TECNA 3324 Scissor Suspended Spot Welding Gun — 23 kVA, Built-In Timer

TECNA 3324 scissor-type suspended spot welding gun — 23 kVA, built-in TE300 timer. Adjustable arms 9.84–25.59 in.; max electrode force 602 lbs (268 daN) at 6 bar.

Description

The TECNA 3324 is a suspended, air-operated scissor production spot welding gun with a built-in TE300 control unit. It pairs a 23 kVA (50% duty) single-phase AC transformer with an adjustable arm length of 9.84–25.59 in. (250–650 mm) and delivers a maximum electrode force of 602 lbs (268 daN) at 6 bar at the shortest arms. Electrodes, electrode holders, arms, transformer, and thyristor are fully water-cooled. The gun is suspended on a balancer for low-fatigue handling across its working envelope.

Features

  • 23 kVA (50% duty) single-phase AC transformer; built-in TE300 control (TE470/TE480 optional).
  • Maximum electrode force 602 lbs (268 daN) at 6 bar (shortest arms).
  • Adjustable arm length 9.84–25.59 in.; force tapers to 254 lbs (113 daN) at the longest arms.
  • Fully water-cooled electrodes, holders, arms, transformer, and thyristor.
  • Lubrication-free pneumatic actuation with adjustable force and speed.
  • Standard supply cables and hoses 21.3 ft (6.5 m) long.

Installation Requirements

  • Electrical supply: Built to order — specify voltage & frequency.
  • Delayed fuses: 40 A; primary cable section 16 mm² (up to 30 m).
  • Recommended spring balancer: 9368BR (121–143 lbs capacity) / 9369BR (143–165 lbs) with long arms.
  • Net weight (with cables, hoses, suspension & shortest arms): 121 lbs (55 kg).

Standard TECNA configuration, built to specified voltage/frequency. US pre-configured builds available as 3324NX (standard cables) and 3324NX/LC (49 ft cables).

Additional information

Weight 121 lbs
Gun Type

Scissor-Type (X-Type)

Standard Control Unit

TE300

Nominal Power 50% (kVA)

23

Max Welding Power (kVA)

52

Max Welding Current (A)

16500

Thermal Current 100% (A)

4250

Secondary Voltage (V)

3.8

Supply

Built to order — specify voltage & frequency

Delayed Fuses (440 V)

40 A

Mains Cable (≤30m, 440 V)

0.02 in² (16 mm²)

Main Cable Length

21.3 ft (6.5 m)

Arm Spacing

8.86 in. (225 mm)

Arm Length Range

9.84–25.59 in. (250–650 mm)

Max Electrode Force

602 lbs (268 daN)

Max Electrode Force @ 6 bar (shortest arms)

602 lbs (268 daN)

Force/Stroke 250mm Arms

602 lbs (268 daN) force; 0.24–0.98 in. (6–25 mm) working stroke; 1.38–1.97 in. (35–50 mm) max stroke

Force/Stroke 350mm Arms

447 lbs (199 daN) force; 0.31–1.34 in. (8–34 mm) working stroke; 1.85–2.76 in. (47–70 mm) max stroke

Force/Stroke 508mm Arms

314 lbs (140 daN) force; 0.47–1.89 in. (12–48 mm) working stroke; 2.56–3.82 in. (65–97 mm) max stroke

Force/Stroke 650mm Arms

254 lbs (113 daN) force; 0.59–2.36 in. (15–60 mm) working stroke; 3.31–4.72 in. (84–120 mm) max stroke

Compressed Air Supply

94 psi (6.5 bar)

Air per 1000 Spots

141 SCF (4 Nm³)

Water Cooling

1.85 gpm (7 lpm)

Req Spring Balancer (short)

9368BR (121–143 lbs)

Req Spring Balancer (long)

9369BR (143–165 lbs)

Power Supply

Actuator Type

Product Type